Easy operation with a large display screen
With 9 operation keys and a large 40 characters x 8 row display screen, it is easier than ever to input programming and parameter settings. The graph display of chromatography signals makes it easy to determine the status of fraction collection.
Reliable construction
The water-sensitive operation panel as well as the mechanical and electronic parts are placed behind the test tube rack to protect against water droplets for a practical, long-lasting design.
Supports different sized collection vessels
The vertical dial allows 70 mm of movement to adjust the dropper nozzle position to the test tube length (105 ~ 180 mm). The standard test tube rack will hold 120 tubes with a diameter of 12 ~15 mm (maximum of 18.1 mm with the standard rack holder removed). Large volume vessels can be set when the rack lid is removed.
Quick nozzle movement with high resolution
A sturdy frame and high resolution stepping motor are used. The nozzle moves accurately to the set position, from tube to tube in 0.1 seconds.
Unneeded constituents drained
Waste constituents are drained out so test tubes are not unnecessarily contaminated.
Safe, chemically resistant material
The exterior of the unit is made of flame retardant ABS plastic, and the test tube rack and drain are made of chemically resistant polypropylene.
Loaded with Unique Collection Functions
Simple mode
Collect by time, drops, volume or signal.
Peak mode
Specify up to a maximum of 10 peaks for identification. Peak determination may be made using a combination of absolute value and slope angle.
Window mode
A maximum of 16 windows (time ranges) may be set so that peaks are identified and fraction collection occurs only within each window. By setting the monitor time, non-peaks may also be collected in the test tubes.
Manual mode
Collect fractions while watching the chromatography signals displayed on the screen. A fraction may be reviewed under playback mode.
Sampling mode
Collect fractions for a set interval during a set period. Multiple collections may be set per test tube.
Multiple sample functions
After a fraction collection has completed, the next fraction sampling begins at the next test tube or after skipping one tube.
Synchronize the chromatogram and collection using the time delay function
Because of the distance from the UV absorption detector, refractometer or other instruments to the fraction collector dispense nozzle, there is a delay from the point of graphing until the sample is collected in the tube. By inputting the lag time, the collected sample can be set to accurately conform to the record (chromatogram).
Verify the fraction collection results by looking at the graph
The results of up to 500 events can be displayed. Chromatography signals are displayed in peak, window and manual modes.
Operate using a computer
Using a computer, the parameter settings for each mode as well as starting, ending, pausing and advancing can be controlled. By loading up to 500 fraction results into the computer, the operation history of the equipment and test results can be easily verified.
Test Tube Rack:
120 tubes (12 ~ 18.1 mm OD x 105 ~ 180 mm L)
Modes:
Simple, Peak, Window, Manual, Sampling
Collection Methods:
By time, Drop count, Signal, Drop volume
Nozzle Shift Time:
Typically 0.1 sec (tube to center)
Wait Time Setting:
999 min 0 sec max.
Delay Time:
9 min 59 sec max.
Simple Mode:
Time 99 min 59 sec/tube max.
Drop 9999 drop/tube max.
Signal 9999 count/tube max.
Volume 999.9 mL/tube max.
Window Mode:
16 windows max.
End time 999 min 59 sec max.
Monitor time 99 min 59 sec / tube max.
Event Marker Output:
Marker ON/OFF (one fraction)
Chromatograph Signal Input:
10 mV or 1 V full scale
Ext. Start Input:
ON start
Ext. Count (Signal) Input:
ON count
Clock:
Quartz oscillation
Display:
LCD (40 characters x 8 rows) w/backlight
Operation Parameter Memory:
Battery back-up
Operating Temperature:
2 - 40°C
Power Requirements:
100 ~ 240 V; 50/60 Hz; 0.23 A max.
Dimensions:
Width x Height x Length
286 x 335 x 387 mm
Weight:
7 kg